cls_main.asp |
本文标签:cls_main.asp <% class cls_main Public ScriptName, SqlQueryNum, savelog, system, ResLicence, ResType, ResLanguage, UserClass, strMsg, RefererPage Public adminName, adminPass, System_Sn, UserTrueIP Public Reloadtime, MaxCount, CacheName, Cache_Data, sPath Private LocalCacheName, CacheData, DelCount, ArrSetting Public MemberUserName, MemberUserID, MemberUserPassword, MemberUserClass, MemberVipType 类初始化 Private Sub Class_Initialize() savelog = 0 设置为1的时候会记录攻击或错误错信息 。 SqlQueryNum = 0 Dim Tmpstr, i Tmpstr = Request.ServerVariables("PATH_INFO") Tmpstr = Split(Tmpstr, "/") i = UBound(Tmpstr) ScriptName = LCase(Tmpstr(i)) RefererPage = Request.ServerVariables("HTTP_REFERER") adminName = Session("adminName") adminPass = Session("adminPass") Reloadtime = 14400 CacheName = Replace(Replace(Replace(Server.MapPath("index.asp"), "index.asp", ""), ":", ""), "\", "") System_Sn = LCase(Replace(Request.ServerVariables("SERVER_NAME") & Request.ServerVariables("URL"), Split(Request.ServerVariables("SCRIPT_NAME"), "/")(UBound(Split(Request.ServerVariables("SCRIPT_NAME"), "/"))), "")) UserTrueIP = Request.ServerVariables("HTTP_X_FORWARDED_FOR") If UserTrueIP = "" Then UserTrueIP = Request.ServerVariables("REMOTE_ADDR") UserTrueIP = checkStr(UserTrueIP) If SystemEdition = 3 Then sPath = "../" Else sPath = "" End If MemberUserName = checkStr(Request.Cookies(System_Sn)("MemberUserName")) MemberUserID = checkStr(Request.Cookies(System_Sn)("MemberUserID")) MemberUserPassword = checkStr(Request.Cookies(System_Sn)("MemberUserPassword")) MemberUserClass = checkStr(Request.Cookies(System_Sn)("MemberUserClass")) MemberVipType = checkStr(Request.Cookies(System_Sn)("MemberVipType")) End Sub 类结束 Private Sub Class_Terminate() If IsObject(Conn) Then Conn.Close Set Conn = Nothing End If End Sub Public Property Let Name(ByVal vNewValue) LocalCacheName = LCase(vNewValue) End Property Public Property Let Value(ByVal vNewValue) If LocalCacheName <> "" Then ReDim Cache_Data(2) Cache_Data(0) = vNewValue Cache_Data(1) = Now() Application.Lock Application(CacheName & "_" & LocalCacheName) = Cache_Data Application.UnLock Else Err.Raise vbObjectError + 1, "Mesky.Cn CacheServer", " please change the CacheName." End If End Property Public Property Get Value() If LocalCacheName <> "" Then Cache_Data = Application(CacheName & "_" & LocalCacheName) If IsArray(Cache_Data) Then Value = Cache_Data(0) Else Err.Raise vbObjectError + 1, "Mesky.Cn CacheServer", " The Cache_Data(" & LocalCacheName & ") Is Empty." End If Else Err.Raise vbObjectError + 1, "Mesky.Cn CacheServer", " please change the CacheName." End If End Property Public Function ObjIsEmpty() ObjIsEmpty = True Cache_Data = Application(CacheName & "_" & LocalCacheName) If Not IsArray(Cache_Data) Then Exit Function If Not IsDate(Cache_Data(1)) Then Exit Function If DateDiff("s", CDate(Cache_Data(1)), Now()) < (60 * Reloadtime) Then ObjIsEmpty = False End Function Public Sub DelCahe(MyCaheName) Application.Lock Application.Contents.Remove (CacheName & "_" & MyCaheName) Application.UnLock End Sub 加载系统配置信息 Public Sub LoadSetting() Dim Rs If Not IsObject(Conn) Then ConnectionDatabase Set Rs = Execute("Select Setting From Mesky_Setting where isDefault=1") ArrSetting = Split(Rs("Setting"), "{$}") Set Rs = Nothing system = Split(ArrSetting(144), ",") ResLicence = Split(ArrSetting(141), ",") ResLanguage = Split(ArrSetting(142), ",") ResType = Split(ArrSetting(143), ",") UserClass = Split(ArrSetting(140), ",") Name = "StyleName" If ObjIsEmpty Then Call ReloadTemplates End Sub Public Function Setting(s) Setting = ArrSetting(s) End Function Public Sub ReloadTemplates() Dim Rs, i Set Rs = Execute("select top 1 * from Mesky_Style where isDefault =1") If Not (Rs.EOF And Rs.BOF) Then For i = 2 To Rs.Fields.Count - 3 Name = Rs(i).Name Response.Write(Rs(i).Name) Value = Rs(i).Value Next End If Set Rs = Nothing End Sub |